1 2 3 4

Transistor, Zener Diode Tester

Make :
ZEAL
Model :
ZMTZDT
     
Transistor Hfe Measurement
Hfe measurement is done at test voltage: 3.6Volt VCC Base current : 8µA Accuracy of test voltage and base current: ±1%

Transistor Iceo Measurement
Range of test voltage : 35 to 130 volt
Range of display of leakage current meter : 1.999mA
Accuracy of test voltage and leakage current : ±1%

Diode Forward Drop Measurement :
Range of test current : 0 to 10Amp Range of forward
drop display: 0 to1.999v Accuracy of Forward drop and Test current: ±1%

Diode Reverse Breakdown Voltage Measurement :
Range of test voltage : 10 to 1000v Accuracy of reveres breakdown voltage indication: ±1%

Zener voltage Measurement
• Range of test voltage: 10 to 1000v@ 25µA
• Accuracy of zener voltage indication: ±1%
• “Transistor, Zener and Diode Tester” is specially designed to measure parameters of numerous of Diodes, Transistors and Zener diodes. It consist parameter selection switches for measuring respective voltage or current for inserted components
• It consist parameter selection switches for measuring respective voltage or current for inserted components.
• This unit has 3 different display to indicated set voltage ,Forward drop voltage, Reverse Breakdown voltage , Iceo and Hfe (gain).